Product Introduction

Product Overview


The UHF Online PD Monitoring System for GIS Switchgear is a cutting-edge solution designed to detect and analyze Partial Discharge (PD) activity in Gas Insulated Switchgear (GIS) systems. By leveraging Ultra High Frequency (UHF) technology with a detection bandwidth of 500–1500 MHz and a dynamic range of -70–10 dB , this system provides real-time insights into the insulation integrity of GIS components, enabling proactive maintenance and minimizing downtime. Partial discharges, often precursors to catastrophic failures in high-voltage equipment, are detected through UHF sensors that capture electromagnetic signals emitted during discharges . The system is engineered to operate in extreme environmental conditions, with a temperature range of -40°F to 185°F and humidity tolerance of 0–100% RH , ensuring reliable performance in both indoor and outdoor substations.


Product Features


Wide UHF Detection Bandwidth

The system’s 500–1500 MHz UHF detection range aligns with industry standards (300 MHz–3 GHz), allowing it to capture a broad spectrum of PD signals generated by common GIS defects, such as free metal particles, insulator cracks, or floating potentials. This wide bandwidth ensures high sensitivity to incipient faults, even in noisy electromagnetic environments.


High Dynamic Range

With a dynamic range of -70–10 dB, the system distinguishes between weak PD signals and background noise, providing accurate and reliable data for diagnostic purposes. This capability is critical for identifying low-level discharges that may escalate into major failures if left undetected .


Environmental Resilience

Built to withstand harsh conditions, the system operates seamlessly across -40°F to 185°F with ±0.5°C accuracy and 0–100% RH with ±2% RH precision . This makes it suitable for applications in extreme climates, including desert regions, coastal areas, and high-altitude locations.


Dual Power Supply Options

The system supports both battery (5+ years standby) and wired power , ensuring continuous operation even during power outages. The long-lasting battery eliminates the need for frequent replacements, reducing maintenance efforts.


Flexible Communication

Equipped with wireless 433 MHz and RS485 interfaces , the system enables remote data transmission to centralized monitoring platforms. This feature facilitates real-time analysis and integration with existing SCADA systems, enhancing operational efficiency.


Compact and Easy Installation

Measuring 121mm × 121mm × 55mm , the system's compact design allows for hassle-free installation using magnetic suction mounting. This non-invasive method ensures quick deployment without disrupting GIS operations, making it ideal for retrofitting existing infrastructure.


Applications


Substation Monitoring

The system is widely used in HV/MV substations to monitor GIS equipment, including circuit breakers, busbars, and insulators. By detecting PD at early stages, it helps utilities prevent unexpected outages and extend equipment lifespan.


Renewable Energy Grids

In solar and wind power plants, where grid stability is critical, the system ensures reliable operation of GIS switchgear connected to step-up transformers. It mitigates risks associated with voltage fluctuations and environmental stressors.


Industrial Facilities

Heavy industries, such as mining and manufacturing, rely on GIS for high-power distribution. The system’s ability to detect PD in real time supports predictive maintenance strategies, reducing production downtime and operational costs.


Transmission Networks

For long-distance power transmission, the system monitors GIS components in HVDC and HVAC networks, ensuring compliance with strict safety and performance standards. Its UHF technology effectively identifies PD sources in complex grid environments.

Parameter

Specification

Ultrasonic Detection

Center frequency: 40±1kHz; Dynamic range: 0–70 dBuV

TEV Detection Bandwidth

3–100 MHz; Dynamic range: 0–60 dBmV

UHF Detection Bandwidth

500–1500 MHz; Dynamic range: -70–10 dB

Noise Detection Range

30–80 dB

Temperature Range

-40°F to 185°F; Accuracy: ±0.9°F

Humidity Range

0–100% RH; Accuracy: ±2% RH

Power Supply

Battery (5+ years standby) / Wired

Communication

Wireless 433 MHz / RS485

Dimensions

121mm × 121mm × 55mm

Installation

Magnetic suction


Contact